Brass Water Meter Body Prepaid Water Meter IC Card Smart Digital Prepaid Water Meter Dry Dial

Brass Water Meter Body Prepaid Water Meter IC Card Smart Digital Prepaid Water Meter Dry Dial

The IC Card series water meter is a kind of prepaid and smart water meter. It’s designed and manufactured by our company and famous design companies both domestic and aboard according to the international standard.
Send Inquiry

Hebei Shanghong Meters Technology Co., Ltd. is one of the leading manufacturers and suppliers of brass water meter body prepaid water meter ic card smart digital prepaid water meter dry dial in China. If you're going to wholesale high quality brass water meter body prepaid water meter ic card smart digital prepaid water meter dry dial, welcome to get pricelist and quotation from our factory.

 


prepaid water meter main picture

PREPAID SYSTEM INTRODUCTION

Overviews

The IC Card series water meter is a kind of prepaid and smart water meter. It’s designed and manufactured by our company and famous design companies both domestic and aboard according to the international standard.

Advantage of the System

·OEM, language display and currency unit display can be customized, and company name can be added to the software.
·The data will be saved automatically after exiting the system.
·Simple management and user card making, easy to query consumption records.
·Invoice printing, providing payment voucher to users in the most common form in the local area.

3/4'' residential sim card smart prepaid water meter with shut off

Brief Introduction

The prepaid water meter have mechanical and electronic readings. It is used to control users overspend by prepaying with an IC card. Pay in advance and then use water get rid of the inconvenience of on-site meter reading and charging.

Product Features

·Our ic card prepaid water meter has high accuracy
·Type:screw,joint,split
·Material: Brass
·Scenes to be used: garden, housing,commercial, general household, residential building,apartment,municipality, household, potable
·Waterproof level:IP68
·Technical data conform to international standard ISO 4064.
·Accuracy:class b
·Fitting:Connctor,PCB,Valve control,Reading device,Adapter,Actuator,Battery operated,Pipe fitting,Connector fitting,Coupling,Pointer,Components,Counter,Rgister
·Communication:IC card reading,Private protocol

Main Technical Data

(Ⅰ) Technical Specifications

Item

Unit

Details

Nominal diameter

mm

15

20

25

Q3/Q1

R80/R100

Overload flow(Q4)

m³/h

3.125

5

7.875

Nominal flow(Q3)

m³/h

2.5

4

6.3

Transitional flow(Q2)

m³/h

0.05

0.08

0.13

Minimum flow(Q1)

m³/h

0.031

0.05

0.08

Accuracy class

Class 2

Maximum indication

99999

Temperature class

T30,T90

Pressure class

MAP 10/MAP16

Pressure loss class

ΔP63

Flow prefile sensitivity class

U10/D5

environmental class

Class B

Electromagnetic environment class

E1

Static current

uA

<10

(Ⅱ) Relative Error

·Maximum permissible error between Q1 and Q2(excluded) is ±5% in flow low area.
·When the water temperature is not higher than 30℃, maximum permissible error between Q2 and Q4(included) is ±2% in flow high area.
·When the water temperature is higher than 30℃, maximum permissible error between Q2 and Q4(included) is ±3% in flow high area.

(Ⅲ) Working Temperature: cold water (0.1~30)℃
(Ⅳ) Operating Ambient temperature: (5~55)℃
(Ⅴ) Storage Environmental temperature: (-5~55)℃

Fault Handling Instructions

Item

Fault display

Fault explanation

Elimination methods

1

Under voltage

Low battery

Contact the manufacturer

2

Flow

Flow sensor signal failure

3

Valve open/close

Valve sticking rusting or scaling

4

Can not read card

Write card erroror take the wrong card

Go to water supply department to test the card

The basic structure principle of IC card water meter

The appearance of IC card water meters is basically similar to that of ordinary water meters, and the installation process is basically the same. The use of IC card water meters is very simple. From the user's point of view, just insert the IC card into the water meter. The working process of the IC card water meter is generally as follows: Insert the IC card containing the amount into the IC card reader in the water meter. After the computer module recognizes and downloads the amount, the valve opens and the user can use water normally. When the user uses water, the water volume acquisition device starts to collect the water consumption, and converts the required electronic signal to the microcomputer module for metering, and displays it on the LCD display module. When the amount of water used by the user drops to a certain value, the microcomputer module gives a sound alarm, prompting the user to pay a fee to buy water with the card. If the amount of water is exceeded, the microcomputer module will automatically close the electric control valve and cut off the water supply. Until the user inserts the paid IC card and reopens the valve for water supply.

Outline Dimensional Drawing

3/4'' residential sim card smart prepaid water meter with shut off

Nominal Diameter

Length L

Length L1

Width B

Height H1

Height H2

Connecting Thread

mm

d

D

15

258

165

90

112

184

R1/2

G3/4B

20

299

195

90

112

184

R3/4

G1B

25

345

225

90

114

186

R1

G1 1/4B

PRODUCT INSTALL

① It is advisable to choose a water meter based on the fact that the frequently used flow rate of the pipeline is less than or close to the common flow rate of the water meter, and the water meter cannot be determined simply by the diameter of the pipeline.

② The installation location should avoid strong sunlight, freezing, and pollution. During the period of freezing, in addition to wrapping the water pipe of the water meter for heat preservation, when not in use, the valve at the water inlet end of the water meter should be closed, and the valve at the water outlet end and the faucet should be opened to prevent the water meter from freezing and cracking. damage.

③ The water meter must be installed horizontally with the face facing up.

④ When installing the pipeline, be sure to wash the stones, silt, hemp and other debris in the pipeline before installing the water meter to avoid water meter failure.

⑤ For accurate measurement, the faucet should be higher than the water meter.

⑥ If the water meter is installed where the boiler enters the water pipe, a check valve should be installed to prevent the backflow of hot water from scalding the water meter.

The water meter should not be directly connected to the pipeline, and there should be movable interfaces between the water meter and the pipeline (such as pipe joints, connecting screws, connection gaskets, etc.). When installing the water meter, it should not be subject to excessive force caused by the pipes and fittings, so as not to damage the water meter.

Precautions for using IC card smart water meter

1. Install a check valve in front of the meter. Since the rotation of the smart water meter is caused by pressure fluctuations and water compression, you can consider installing a check valve. The check valve can prevent water from flowing backwards. In this way, when the pressure rises, the water is compressed, and the water meter rotates positively; when the pressure drops, the check valve closes automatically, and the water meter does not rotate. When the pressure rises again, as long as the pressure is not higher than the pressure in the check valve, the water meter will not turn again; the water meter rotates mainly because the water meter reciprocates and measures many times to accumulate a large amount of water. Installing a check valve can reduce the pressure of the smart water meter. The frequency of rotation can well solve the problem of water meter rotation caused by pressure fluctuations. However, due to the high frequency of domestic water use and the small fluctuation of pipeline pressure, the check valve is required to have high sensitivity and high quality requirements.

2. Arrange the exhaust valve reasonably according to the characteristics of the pipeline during design, and remove the gas precipitated in the pipeline in time; gas content.

3. For newly installed household meters, when installing the pipes in the residents’ homes, the pipes should be laid upwards along the corresponding angle to reduce the bending points and folding points of the pipes, and the high point of the pipes should be designed on a frequently used faucet to reduce the Chance of air pockets in the pipe network.

4. When the smart water meter is out of the house, it may cause the change of the water inlet direction of the user's home, resulting in some dead water pipes indoors. Protruding pipe sections are prone to air pockets, and these pipe sections should be removed or remodeled during construction.



 

_09

_10

_12


Hot Tags: brass water meter body prepaid water meter ic card smart digital prepaid water meter dry dial, manufacturers, wholesale, pricelist, quotation, DN40 Prepaid Water Meter Smart Reading IC Card Smart Digital Prepaid Water Meter, IC Card Swipe Card Prepayment Water Meter Factory Wholesale For Urban And Rural Civilian, Prepaid Water Meters, IC Card Prepaid Smart Water Meter, RF Card Prepaid Water Meter Wholesalers