Hebei Shanghong Meters Technology Co., Ltd. is one of the leading manufacturers and suppliers of 200mm flange ultrasonic water meters wireless display in China. If you're going to wholesale high quality 200mm flange ultrasonic water meters wireless display, welcome to get pricelist and quotation from our factory.
Product Description

It is a metering instrument to continuously measure, record, and display the volume of water flowing through the sensor by use of the ultrasonic time difference method. Please read this manual carefully before use, to use it to the best advantage and avoid unnecessary loss.
Product features
▲Unaffected by impurities, chemicals, and magnetic materials in the medium;
▲Low starting rate (33L/h), able to accurately measure the flow rate;
▲High measurement frequency;
▲Flow rate can be as low as 100L/h;
▲Dynamic range (Q3/Q1) up to 250:1;
▲Installed in any installation position;
▲Bidirectional metering;
▲Display of error and alarm codes;
▲Optional battery supply;
▲Material ductile cast iron;
▲No moving parts, high accuracy, and years of service life. The flow sensor has no moving parts, avoiding instrumentation failures of mechanical parts that can lead to inaccurate measurements due to long-term wear. The design is also resistant to impurities, making it inspection and maintenance-free;
▲Low-pressure drop;
▲IP68 protection class can adapt to a variety of harsh installation environments;
▲Support RS485 communication, pulse output, GPRS, NB-IOT, LoraWan, and other data transmission methods.
technical parameter
|
Nominal diameter(mm) |
50 | 65 | 80 | 100 | 125 | 150 | 200 | 250 | 300 | ||||||||||||||||||||||||
|
Max flow Q4(m³/h) |
31.25 | 50 | 78.75 | 125 | 200 | 312.5 | 500 | 787.5 | 1250 | ||||||||||||||||||||||||
|
Nominal flow Q3(m³/h) |
25 | 40 | 63 | 100 | 160 | 250 | 400 | 630 | 1000 | ||||||||||||||||||||||||
|
Transitional flow Q2(m³/h) |
0.16 | 0.256 | 0.4 | 0.64 | 1.024 | 1.6 | 2.56 | 4.03 | 6.4 | ||||||||||||||||||||||||
|
Min flowQ1(m³/h) |
0.1 | 0.16 | 0.252 | 0.4 | 0.64 | 1 | 1.6 | 2.52 | 4 | ||||||||||||||||||||||||
|
Start-up flow(m³/h) |
0.033 | 0.06 | 0.09 | 0.14 | 0.21 | 0.31 | 0.56 | 0.88 | 1.2 | ||||||||||||||||||||||||
|
Max flow |
9999999.9 |
||||||||||||||||||||||||||||||||
|
Reverse flow |
9999999.9 |
||||||||||||||||||||||||||||||||
|
Measuring range |
Q3/Q1, R250(R400 customizable) |
||||||||||||||||||||||||||||||||
|
Accuracy class |
Class B |
||||||||||||||||||||||||||||||||
|
Pressure loss class |
≤0.063 MPa |
||||||||||||||||||||||||||||||||
|
Working pressure |
1.6 MPa |
||||||||||||||||||||||||||||||||
|
Temperature class |
T30 |
||||||||||||||||||||||||||||||||
|
Temperature range |
(5~55)℃ |
||||||||||||||||||||||||||||||||
|
Environment class |
Indoor, Class B |
||||||||||||||||||||||||||||||||
|
Electromagnetic class |
E1(Residential, Commercial, Industrial) |
||||||||||||||||||||||||||||||||
|
Power supply |
Built-in lithium battery DC 3.6V |
||||||||||||||||||||||||||||||||
|
Battery life |
> 10years |
||||||||||||||||||||||||||||||||
|
Installation position |
Any angle |
||||||||||||||||||||||||||||||||
|
Display |
LCD, 8 digits + additional characters |
||||||||||||||||||||||||||||||||
|
Flow profile sensitivity class |
U10/D5 |
||||||||||||||||||||||||||||||||
|
Communication interface |
RS485 Modbus/ Pulse output/GPRS/NB-IOT/Lorawan |
||||||||||||||||||||||||||||||||
|
Protection class |
IP68 |
||||||||||||||||||||||||||||||||
|
Tolerable storage temperature |
-20~60℃ |
||||||||||||||||||||||||||||||||
|
Static power |
10μA |
||||||||||||||||||||||||||||||||
|
Operating power consumption |
45μA |
||||||||||||||||||||||||||||||||
meter display content
P1: In the last interface of P1, keep covering the sensing area for more than 3S to enter P2 and repeat this operation to enter P3 , P4

P2: Cumulative flow of the historical month

P3: For internal debugging and testing, it does not have any meaning.
P4: Test status

| Mode | No. | Display Description |
| P1 | 1 | Cumulative flow |
| 2 | Temperature | |
| 3 | Size | |
| 4 | Flow rate | |
| 5 | Negative cumulative flow | |
| 6 | Net cumulative flow | |
| 7 | Working time | |
| 8 | Sensor status | |
| 9 | Power voltage | |
| P2 | Cumulative flow of the historical month | |
| P3 | For internal debugging and testing, it does not have any meaning | |
| P4 | 1 | Cumulative flow |
| 2 | Coefficient | |
| 3 | Flow rate | |
| 4 | Working time | |
Note: The display interface of the meter is subject to change for customization or upgrading.
factory

packaging and inventory

our client

Hot Tags: 200mm flange ultrasonic water meters wireless display, manufacturers, wholesale, pricelist, quotation, IP68 Double Flange Ultrasonic Water Meter Support Integrate System Forresidential Building, Large caliber Ultrasonic Remote Water Meter, Remote Reading Ultrasonic Water Flow Meter, RS485 Water Meter Wireless Remote Digital High Accuracy Ultrasonic Cold Water Meter, Ultrasonic Smart Remote Water Meter, Wireless Remote Iso 4064 Class B Digital 200mm Flange Ultrasonic Smart Water Meter