Hebei Shanghong Meters Technology Co., Ltd. is one of the leading manufacturers and suppliers of hot cold electromagnetic flowmeter magnetic flow meter in China. If you're going to wholesale high quality hot cold electromagnetic flowmeter magnetic flow meter, welcome to get pricelist and quotation from our factory.





Technical Performance Parameters
Main Power | AC220V 50Hz /DC24V/3.6V | |
Power consumption | <15W(Supporting power consumption with sensors) | |
Display and buttons | Display in Chinese and English can display instantaneous flow, cumulative flow, and alarm display (excitation open circuit alarm, empty pipe alarm, flow limit alarm). 4 membrane touch switches for data sets | |
Counter | Forward total, reverse total | |
Output Signal | Analog output | Two-way, fully isolated 0~10mA/4~20mA |
Load resistance: 0 ~ 1.5kΩ when 0 ~ 10mA; 0 ~ 750Ω when 4 ~ 20mA | ||
Frequency output | Forward and reverse flow output, the upper limit of output frequency can be set within 1 ~ 5000Hz. Open collector bidirectional output of transistor with photoelectric isolation. The external power supply is not greater than 35V, and the maximum current of the collector when conducting is 50mA. | |
Alarm Output | Two open-collector alarm outputs with photoelectric isolation transistors. The external power supply is not greater than 35V, and the maximum current of the collector when it is turned on is 250mA. Alarm status: fluid empty pipe, excitation disconnection, flow overrun. | |
Pulse output | Forward and reverse flow output, the upper limit of output pulse can reach 5000CP / S. The pulse equivalent is 0.0001 ~ 1.0m³ / P. The pulse width is automatically set to 20ms or square wave. Open collector output of transistor with photoelectric isolation. External power supply is not greater than 35V, the maximum current of the collector when conducting is 50mA | |
Matching accuracy | ± 0.5% of market value, optional ± 0.2% or 1% of indicated value | |
Damping time constant | Continuous variable from 0 ~ 100s (90%) time grading optional | |
communication | Optional RS232C or RS485 serial communication interface, HART communication protocol, with anti-lightning protection | |
Loss of power | The internal design of the instrument has a power-off clock, which can store 16 drop-out records (10 years) | |
Protection level | IP65 | |
Explosion-proof mark | Exs[ia]ia||cT5 | |

Lining Material
Material | Main Performance |
Polyurethane rubber | 1. Very good wear resistance coal slurry, mud, ore slurry, etc. 2. Not resistant to acid, alkaline, and other corrosive or high-temperature media 3. There must be no negative pressure in the pipeline |
Neoprene | 1. Very good elasticity and wear resistance 2. Capable of measuring domestic sewage, non-corrosive industrial sewage PH value: in the range of 6/7/8, temperature below 80 ℃ liquid 3. There must be no negative pressure in the pipeline |
Teflon F-4 PTFE | 1. Boiling-resistant hydrochloric acid, sulfuric acid, nitric acid, aqua regia, concentrated alkali, and various organic solutions 2. Strong abrasion resistance and poor bonding performance 3. There must be no negative pressure in the pipeline |
Perchloroethylene propylene F-46(PTFE) | 1. On the basis of all functions of PTFE, the temperature of the non-corrosive liquid can be increased within 140 degrees 2. Not resistant to fuming nitric acid, butyl lithium 3. There must be no negative pressure in the pipeline |
Silicone fluoride lining | Temperature resistance: 70 degrees, mainly high temperature. It can be used to measure hot water in heating systems and is not resistant to corrosion. |
Electromagnetic Flowmeter Electrode Material |
Electromagnetic flowmeter electrode material:
| material | material Corrosion performance |
| 316L electrode | Application: domestic / industrial water, sewage PH value: within 6/7/8 Not applicable: corrosive media such as hydrofluoric acid / hydrochloric acid / chlorine / iodine |
| HB | Application: certain concentration of hydrofluoric acid and other oxidizing acids and non-oxidizing hydrochloric acid, alkali solution with a concentration of not less than 70% sodium hydroxide. PH value: within 5/6/7/8 Not applicable: Oxidizing acids such as nitric acid |
| HC | Application: corrosion resistance to oxidizing salts or environments containing other oxidants, especially to seawater. PH value is within: 6/7/8/9 Not applicable: hydrochloric acid, dilute sulfuric acid, phosphoric acid and other reducing acids and chlorides |
| Ti | Application: chloride, hypochlorite, sea water, oxidizing acid. PH value: within the range of 6/7/8/9/10 Not applicable: hydrochloric acid, sulfuric acid and other acidic media |
| Ta | Application: concentrated hydrochloric acid, nitric acid, sulfuric acid and other acid liquids, including boiling hydrochloric acid and nitric acid. PH value: within 3/4/5/6 Not applicable: alkali, hydrofluoric acid, fuming sulfuric acid |
| Pt | Various acids, bases, salts. Not included: Royal Water |

Requirement for the Surrounding
1. The electromagnetic flow meters should not install the place where the temperature change a lot, or the place been high-temperature radiation.
2. The installation place for the electromagnetic flow meters more better if inside of house, if must be install outside, it should be avoid the rain and heavy water, and sunshine, it should have damppoof and sunscreen.
3. The electromagnetic flow meters should be avoid to install the place where is have corrosivity air, if can’t avoid the corrosivity air, it should have ventilate solution.
4. When install the electromagnetic flow meters, it should be guarantee the surrounding have enough space to install and repair.
5. The install place for the electromagnetic flow meters should be avoid the magnetic field and heavy vibration, if the pipeline have the heavy vibration, it request install the support equipment to steady the meters.



Hot Tags: hot cold electromagnetic flowmeter magnetic flow meter, manufacturers, wholesale, pricelist, quotation, Electromagnetic Magnetic Flow Meter For Wastewater Applications Price, Digital Anti corrosion Double Electric Grade Electromagnetic Flow Meter, Hot Cold Electromagnetic Flowmeter Magnetic Flow Meter, China Digital Insertion Electromagnetic Liquid Water Magnetic Flow Meter For Irrigation, IP68 Electromagnetic Flow Meter Manufacturer Industrial Water Dirty Water Flow Meter Suppliers